Renato Murata |
PhD student, DTIS, ONERA, Université Paris Saclay, F-91120 , Palaiseau, France. | Julien Marzat |
Research Scientist, DTIS, ONERA, Université Paris Saclay, 91120, Palaiseau, France. | Hélène Piet-Lahanier |
Research Scientist, DTIS, ONERA, Université Paris Saclay, 91120, Palaiseau, France. | Sandra Boujnah |
Research Scientist, Sous-Direction Techniques Systèmes de Transport Spatial, CNES, 75612, Paris, France. | François Farago |
Research Scientist, Sous-Direction Techniques Systèmes de Transport Spatial, CNES, 75612, Paris, France. |
|
Abstract:
This paper presents a comparison between three state observer schemes, including a nonlinear high-gain observer, a Luenberger observer, and an unknown input observer, in order to detect and isolate leaks in the propellant feeding system of a reusable launcher. The results show that the high-gain observer had the best overall performance. On the other hand, due to decoupling strategies, the bank of unknown input observers generates a more robust fault signature matrix. Monte Carlo experiments under realistic measurement noise assumptions are included to compare the proposed approaches.
|